PRODUCTS

M-1

M-1, our one-loop analog addressable fire alarm control panel can support up to 126 XP95 and Discovery or up to 252 CoreProtocol analog addressable devices as well as a range of call points, detectors, interfaces, beacons, and loop sounders.

With a large capacity, it is designed to support complex cause-and-effect programming and an extensive range of user-controllable functions. 

Application Environment

Oil & Gas

Power & Utilities

Hospitals

Retail

Hotels

Skyscrapers

Smart & Safe City

Manufacturing

Download Datasheet

Download
Catalog

M-1, our one-loop analog addressable fire alarm control panel can support up to 126 XP95 and Discovery or up to 252 CoreProtocol analog addressable devices as well as a range of call points, detectors, interfaces, beacons, and loop sounders.
With a large capacity, it is designed to support complex cause-and-effect programming and an extensive range of user-controllable functions.
Its components all operate as part of a fully-integrated system, with the panel, detectors, interfaces, and other ancillaries working in full compatibility. The MA series of products feature networking capabilities and proprietary MTech software that make it is easy to use and configure, from the smallest to large sites.

Multiple-stage and complex cause-and-effect programming:  a wide range of user-controllable functions and three stages of cause-and-effect programming per output device which meet the needs of diverse, small-to-large-scale projects. 

Full system integrity also in the event of an external short-circuit fault: when a short-circuit is detected, isolators on the devices closest to the problem automatically isolate the fault, and drive communication from both ends of the loop to sustain full communication with all system devices. 

System can be extended using local network communications to include conventional panels, while maintaining full control of inputs and outputs from the M-1.

Complies with NFPA Standard 72 requirements, and listed by Underwriters Laboratories under the UL864 10th Edition.

  • Simple and comprehensive four-row graphic display
  • Easy installation and maintenance
  • Internal self-testing device that is operated manually
  • Quick scan of analog values of detectors connected to and report exported to excel
  • Improved protection against false alarms (in case of ground fault or strong noise)
  • Flexible programming abilities using virtual zones
  • 1-second response to alarm or network failure
  • Isolated from noise
  • Protected from network communication data loss
  • Can be programmed on site or by using the MTech site installer software on PC

Technical Specifications:

Code M-1
Description Analog Addressable Fire Alarm Control Panel, UOJZ.S36158
Standards for panels SII1220 and TR TC EAC 043-2017
Ready to work with UL267 7th Edition analog addressable smoke detector
Specification
Panel display 4-line x 16-character LCD, multilingual support
Panel keyboard Full numeric keyboard, Reset, Silence, Info, ACK, Enter, ESC, Navigation Rows
Panel indication LED indication: AC, Alarm, Trouble, Silence, Supervisory, Disable, Dialer Fault, Ground Fault and an addition 8 indications that can be configured by client
Sound Internal alarm sounder
Number of loops 1 SLC loops class A
Loop powered outputs 700 mA power for loop
Addresses per loop up to 126 XP95 and Discovery addressable devices and up to 252 CoreProtocol addressable devices
Programming port USB port for PC communication
Output ports RS485 and RS232
Network MA-NET network card for RS-485 network for communication up to 64 panels in network with global correlation matrix
MA-TCP/IP – network card for TCP/IP network
LNET/RS-485 for communication of up to 32 Conventional MB-202, 204 and 208 panels or/and up to 4 remote annunciators MA-1050A per FACP
Event history Buffer for 2,000 events with date and time stamp

and 10,000 events in MA-NET card buffer

Service Built-in walk test
Power 
Input voltage Input 120VAC 3.2A / 230VAC 1.6A; 50/60Hz
Operated voltage 24VDC 6.5A
Battery Two 12V 7 Ah or two 12V 12 Ah (dependent)
Input
Programmable Two addressable inputs on board
DRC dry contact control (for door tamper switches)
Output 
Panel sounder circuit 1 O/P NACs (600mA)
Panel auxiliary outputs AUX 24VDC 2A, AUX resettable 24VDC 300mA
Panel Relays alarm (1), trouble (1), programmable (3)
Physical
Environmental operating temperature 0 – 49°C
Humidity (non-condensing) 0 – 93% RH
Physical construction Metal box
Color RAL 3000
Weight 7 kg
Ingress protection IP31
Cable entries: top (4), right (3), left (1)
Compatibility
Suitable for use with MTech MA Analog Addressable Fire System
MTech MB Conventional Fire System
MA-1050A Remote Annunciator
MA-Monitoring Graphical Management Software

M-1 – English version

M-1RUS – Russian version