MTech’s MB 200 series of Conventional Fire Alarm Control Panels includes three products: MB 202, MB 204 and MB 208, with 2, 4 and 8 Class B zones respectively.
MB control panels are compatible with conventional input devices such as smoke detectors, manual pull stations, water-flow devices, tamper switches, and other normally-open contact devices. They are simple to install and operate, and provide a flexible, cost-effective solution for projects the require conventional systems.

Application Environment

Oil & Gas

Power & Utilities

Hospitals

Retail

Hotels

Skyscrapers

Smart & Safe City

Manufacturing

Download Datasheet

Download
Catalog

MTech’s MB 200 series of Conventional Fire Alarm Control Panels includes three products: MB 202, MB 204 and MB 208, with 2, 4 and 8 Class B zones respectively.
MB control panels are compatible with conventional input devices such as smoke detectors, manual pull stations, water-flow devices, tamper switches, and other normally-open contact devices. They are simple to install and operate, and provide a flexible, cost-effective solution for projects the require conventional systems.

2-wire connection per zone
2-wire connection for repeaters and ancillary boards
Come with four Class B notification appliance circuits (NAC), programmable relays, dedicated alarm and trouble relays, multiple ports and NAC protocol capable of programming outputs
Ability to silence audible devices straight from the panel, while strobes continue to flash
Call-point can perform cross-zone overwrite
Build-in device programmer
Improved protection against false alarms (in case of ground fault or loud noise)
Can integrate with Eaton devices to create sophisticated cross-zone functionality
Panels comply with NFPA Standard 72, and listed by Underwriters Laboratories under the UL864 10th Edition

Approved as Releasing Panels according UL 864 10th Edition and NFPA 2001 requirements

  • Simple installation and integration
  • Includes maintenance notifications
  • Compatible with wide range of detection devices including Eaton products
  • Cross-detection alarm in the zone
  • Can be programmed on site or by using the MTech site installer software on PC

Technical Specifications:

Code MB-202 MB-204 MB-208
Description Conventional Fire Alarm Control Panel, UOJZ.S36158
Extinguisher Water and Agent Releasing Support SYZV.S36158
Standards UL864 10th Edition, SII1220 and TR TC EAC 043-2017
Specification
Panel display 2-line x 16-character LCD, multilingual support
Panel keyboard Full numeric keyboard, Reset, Silence, Forward, ESC, Enter
Panel indication LED indication: AC, Alarm, Trouble, Silence, Supervisory
Sound Internal alarm sounder
Number of zones 2 4 8
Devices per zones 20
Output ports RS485
Network LNET/RS-485 – for communication with remote annunciator MA-1050A
LNET/RS-485 – for communication with analogue addressable system up to 32 conventional MB-202, 204 and 208 panels
LNET/RS-485 – for communication with analog addressable MA fire alarm panels
Event history Buffer for 250 events with date and time stamp
Service Built-in walk test
Power
Input voltage Input 120VAC /230VAC; 50/60Hz
Operated voltage 24VDC 6.5A
Battery Two 12V up to 20Ah
Output
Panel NACs 4 O/P NACs (600mA)
Panel relays Alarm (1), Trouble (1), Programmable (3)
Initiating end-of-line resistor Zone, 4.7K Ohms 1/2W 5%,

NAC, 10K Ohms 1/2W 5%,

Physical
Environmental operating temperature 0 – 49°C
Humidity (non-condensing) 0 – 93% RH
Physical construction Metal box
Color RAL 3000
Weight 7 kg
Ingress protection IP31
Cable entries: Top (4), Right (11), Left (2)
Compatibility
Suitable for use with MA-1050A Remote Annunciator
  MTech Analog Addressable Fire System
MA-Monitoring Graphical Management Software
UL864-10th-Edition-MA-1000-MA-1-MB-202204-208-MA-1050A-MA-1050NET-MA-IOR-MA-NET.pdf
SII1220-MB-202-204-208.pdf
EACGOST-R-MA-1000-MB-202204208400-MA-NET-MA-1050A-MA-IN-OR-IOR-MA-ZONE-MA-300320330340-MA-BABS-BSH-MA-CPMA-S.pdf

MB-202 (2- Zone, English version)
MB-204 (4- Zone, English version)
MB-208 (8- Zone, English version)
MB-202RUS (2- Zone, Russian version TR TC EAC)
MB-204RUS (4- Zone, Russian version TR TC EAC)
MB-208RUS (8- Zone, Russian version TR TC EAC)